McGee highlights crane safety shortfall…

UK contractor transparency sheds light on potential crane safety design flaw.

Major UK contractor McGee Group Ltd has maintained the admirable trend towards publicly sharing its post accident investigation findings, issuing a safety alert to ensure that its workers and those of its fellow demolition contractors are aware of a potential shortcoming in a key crane safety system:

On the evening of Friday 1st December on a major project in London, a 130 Tonne Tadano Faun ATF110G-5 Mobile Crane supplied by Baldwins Crane Hire, up–ended and came to rest on two steel columns.

Fortunately nobody was injured and no major damage was sustained to either the crane or any element of the structure. The investigation is still ongoing, however early indications have revealed that human error was a main contributory factor.

A number of issues have been raised which relate to the inspection regime in respect of the crane rigging and the inspections carried out before the crane went to work.

The purpose of this alert is to raise the awareness on a matter relating to Load Moment Device (LMD)

Our initial investigations have revealed that there is no fail safe device fitted, beyond the LMD to capture wrongly entered data, as a consequence if the wrong counter weight detail is entered and exceeds that which has been actually installed, the audible and visual warning devices will not activate.

Both the crane supplier and ourselves have been in contact with several crane manufacturers and are alarmed to discover that this would appear common place.

To ensure that the crane operator enters the correct codes into the LMD to identify the actual counter weight fitted, it may be necessary to amend your procedures i.e. pre-use check sheets to include a provision for secondary sign off.

McGee personnel can refer to our safe operating procedures (lifting operations) which is available on our Livelink management system, for guidance on the new requirement.

One manufacturer has advised that there are various options available at “point of sale” that can be installed such as outrigger length measuring devices and ballast sensors, but current EU regulations do not require this.

We intend to discuss with the HSE changes required in the regulations to enforce the requirement for ballast sensors on all mobile cranes going forward.

As previously stated, this investigation is still on-going and if any other pertinent information comes to light, we will advise accordingly.